{"product_id":"chamsys-genetix-gw2o-dmx-out-wall-mount-node-2-port","title":"ChamSys GeNetix GW2O DMX Out Wall Mount Node 2-Port","description":"\u003cp\u003eChamSys GeNetix GW2O DMX Out Wall Mount Node is a two-port, PoE-powered DMX\/RDM wall mount node designed for permanent lighting installations. It fits a standard single-gang US back box and features two 5-pin XLR female DMX\/RDM ports, along with a network terminal connection for reliable lighting control and signal distribution.\u003c\/p\u003e\r\n\u003cdiv class=\"iframe-container\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Uu7hH98YJts\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\r\n\u003cp\u003eSupporting Art-Net, DMX512, and SACN protocols, the ChamSys GeNetix GW2O provides flexible integration with professional lighting networks. It offers web server remote configuration, ChamNet support, configurable DMX timings, and DMX redundancy support. Compatible ChamSys consoles and Art-Net connections allow convenient setup and configuration for a variety of lighting applications.\u003c\/p\u003e\r\n\u003cp\u003eDesigned for convenient installation, this compact wall mount node is available in versions for US, UK, and EU single-gang back boxes. It includes interchangeable black and white faceplates to suit different installation environments. Weighing just 0.33 lb (0.15 kg), the ChamSys GeNetix GW2O is a practical solution for theaters, venues, and other permanent lighting control systems. It does not unlock demo mode on MagicQ PC systems.\u003c\/p\u003e\r\n\u003ch1\u003eKey Features\u003c\/h1\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eTwo-port DMX\/RDM wall mount node for permanent installations.\u003c\/li\u003e\r\n\u003cli\u003ePoE-powered design for convenient installation.\u003c\/li\u003e\r\n\u003cli\u003eSupports Art-Net, DMX512, and SACN protocols.\u003c\/li\u003e\r\n\u003cli\u003eTwo 5-pin XLR female DMX\/RDM ports.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch1\u003eIdeal For\u003c\/h1\u003e\r\n\u003cul\u003e\r\n\u003cli\u003ePermanent lighting installations.\u003c\/li\u003e\r\n\u003cli\u003eTheaters and performing arts venues.\u003c\/li\u003e\r\n\u003cli\u003eConcert halls and live event spaces.\u003c\/li\u003e\r\n\u003cli\u003eCommercial buildings and entertainment venues.\u003c\/li\u003e\r\n\u003cli\u003eProfessional DMX lighting control systems.\u003c\/li\u003e\r\n\u003cli\u003eArt-Net and SACN lighting networks.\u003c\/li\u003e\r\n\u003cli\u003eChamSys console-based lighting setups.\u003c\/li\u003e\r\n\u003cli\u003eInstallations requiring remote configuration and DMX redundancy.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch1\u003eWhat's in the Box\u003c\/h1\u003e\r\n\u003cul\u003e\r\n\u003cli\u003eChamSys GeNetix GW2O DMX Out Wall Mount Node (2-Port)\u003c\/li\u003e\r\n\u003cli\u003eBlack Face Plate\u003c\/li\u003e\r\n\u003cli\u003eWhite Face Plate\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch1\u003eInputs \u0026amp; Outputs\u003c\/h1\u003e\r\n\u003cul\u003e\r\n\u003cli\u003e2 × 5-pin XLR female DMX\/RDM ports.\u003c\/li\u003e\r\n\u003cli\u003e1 × punchdown network terminal input.\u003c\/li\u003e\r\n\u003cli\u003eSupports DMX512, Art-Net, and SACN protocols.\u003c\/li\u003e\r\n\u003cli\u003eSupports DMX input or output functionality.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhat is the ChamSys GeNetix GW2O DMX Out Wall Mount Node?\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eIt is a two-port PoE-powered DMX\/RDM wall mount node designed for permanent lighting installations.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eWhich lighting protocols does it support?\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eIt supports Art-Net, DMX512, and SACN protocols.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHow many DMX ports does it have?\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eIt features two 5-pin XLR female DMX\/RDM ports.\u003c\/p\u003e\r\n\u003cp\u003e\u003cstrong\u003eHow can the node be configured?\u003c\/strong\u003e\u003c\/p\u003e\r\n\u003cp\u003eIt supports configuration through its built-in web server, compatible ChamSys consoles, or Art-Net.\u003c\/p\u003e\r\n\u003ch1\u003eFull Technical Specifications\u003c\/h1\u003e\r\n\u003ch2\u003eAudio Performance\u003c\/h2\u003e\r\n\u003ctable width=\"660\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eBrand\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eChamSys\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eProduct Name\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eGeNetix GW2O DMX Out Wall Mount Node\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eProduct Type\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eWall Mount DMX\/RDM Node\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eDMX\/RDM Ports\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e2 × 5-Pin XLR Female\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eNetwork Ports\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e1 × Punchdown Terminal Connector\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eInputs\/Outputs\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e2 × XLR 5-Pin DMX Female Output, 1 × Terminal Input\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eSupported Protocols\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eArt-Net, DMX512, sACN\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003ePower Supply\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003ePower over Ethernet (PoE)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eWeb Server\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eRemote Configuration\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eChamNet Support\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eConfigurable DMX Timings\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eDMX Redundancy Support\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eDimming\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eOptional\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eCooling System\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eNone\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eFixture Compatibility\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eCompatible ChamSys Consoles and Lighting Networks\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eInstallation Type\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003ePermanent Wall Mount\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eConnectors\u003c\/h2\u003e\r\n\u003ctable width=\"660\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eDMX\/RDM Ports\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e2 × 5-Pin XLR Female\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eNetwork Connection\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e1 × Punchdown Terminal Connector\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eDMX Protocols\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eDMX512, Art-Net, sACN\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eNetwork Support\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eChamNet\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003ePower Connection\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003ePower over Ethernet (PoE)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eConfiguration\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003eBuilt-in Web Server\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003ePower \u0026amp; Operation\u003c\/h2\u003e\r\n\u003ctable width=\"660\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003ePower Source\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003ePower over Ethernet (PoE)\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003ePoE Powered\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003ePower Consumption\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eNot Specified\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eOperating Mode\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eDMX\/RDM Wall Mount Node\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eSupported Protocols\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eArt-Net, DMX512, SACN\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eConfiguration\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eBuilt-in Web Server, Compatible ChamSys Consoles, or Art-Net\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eChamNet Support\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eYes\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eDMX Timing\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eConfigurable\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eDMX Redundancy\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eSupported\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eDimming\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eOptional\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"192\"\u003e\r\n\u003cp\u003eCooling System\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"468\"\u003e\r\n\u003cp\u003eNone\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e\r\n\u003ch2\u003eDimensions \u0026amp; Weight\u003c\/h2\u003e\r\n\u003ctable width=\"660\"\u003e\r\n\u003ctbody\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eDimensions:\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e(L × W × H): 5.53 x 2.76 x 1.48\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n\u003ctd width=\"220\"\u003e\r\n\u003cp\u003eWeight\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003ctd width=\"440\"\u003e\r\n\u003cp\u003e0.33 lbs\u003c\/p\u003e\r\n\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003c\/tbody\u003e\r\n\u003c\/table\u003e","brand":"ChamSys","offers":[{"title":"Default Title","offer_id":71665957142781,"sku":"H-CHAM-GENETIXGW2OUS","price":395.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0617\/2308\/3005\/files\/2122742.jpg?v=1792691912","url":"https:\/\/hollywooddj.com\/products\/chamsys-genetix-gw2o-dmx-out-wall-mount-node-2-port","provider":"Hollywood DJ","version":"1.0","type":"link"}